Part Number Hot Search : 
FZT658 IP137A 40ST1041 SB150 BSS84N3 2SC4709 BU4506DF TOP221GN
Product Description
Full Text Search
 

To Download G6D-1A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Power PCB Relay
Reduced board space ideal for highdensity mounting (45% smaller than the surface area of G6B) s Slim package: measures 6.5 W x 17.5 L x 12.5 H mm (0.26 x 0.69 x 0.49 in) s Switches loads up to 5 A, 250 VAC/ 30 VDC
s
G6D
Fully sealed construction allows automatic soldering and cleaning s Long service life: up to 300,000 operations with a 2 A, 250 VAC/30 VDC load
s
Rated for D150 pilot duty by UL, CSA s Optional mounting socket simplifies relay installation and servicing of finished equipment
s
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6D-1A-DC12). Type Standard Contact form SPST-NO Terminal PCB Construction Fully sealed Part number G6D-1A
s ACCESSORIES
Connecting Socket Description PCB mount socket for G6D relay Part number P6D-04P
Specifications
s CONTACT DATA
Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 5 A at 250 VAC, 30 VDC Ag alloy 5A 250 VAC, 30 VDC 5A 1,250 VA, 150 W 10 mA at 5 VDC Inductive load (p.f. = 0.40, L/R = 7 ms) 2 A at 250 VAC, 30 VDC
500 VA, 60 W
G6D
s COIL DATA
Rated voltage (VDC) 5 12 24 Rated current (mA) 40 16.7 8.3 Coil resistance () 125 720 2,880 Pick-up voltage % of rated voltage 70% max. 10% min. 130% at 70C (158F) Dropout voltage Maximum voltage
G6D
Power consumption (mW) Approx. 200
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C (73F). 3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down.
s CHARACTERISTICS
Contact resistance Operate time Release time Bounce time Operating frequency Insulation resistance Dielectric strength 100 m max. 10 ms max. (mean value: approx. 4.30 ms) 10 ms max. (mean value: approx. 5.50 ms) Mean value: approx. 1.20 ms 18,000 operations/hour 1,800 operations/hour (under rated load) 1,000 M min. (at 500 VDC) 3,000 VAC, 50/60 Hz for 1 minute between coil and contacts 750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity 6,000 V, 1.20 x 50 s between coil and contacts 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 2 hours 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 5 minutes 1,000 m/s2 (approx. 100 G) 100 m/s2 (approx. 10 G) -25 to 70C (-13 to 158F) 45% to 85% RH 20 million operations min. (at operating frequency of 18,000 operations/hour) See "Characteristic Data" Approx. 3 g (0.10 oz)
Operate Mechanical Electrical
Surge withstand voltage Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating Humidity Life expectancy Mechanical Electrical Weight Note: Data shown are of initial value.
s CHARACTERISTIC DATA
Maximum switching capacity Life expectancy Ambient temperature vs. maximum voltage
Life expectancy (x103 operations)
Maximum voltage (%)
Switching current (A)
Switching voltage (V)
Switching current (A)
Ambient temperature (C)
2
G6D
G6D
Dimensions
Unit: mm (inch)
s RELAYS
G6D-1A Terminal arrangement/ Internal connections (Bottom view)
Mounting holes (Bottom view) Tolerance: 0.1 (0.04)
s SOCKET
P6D-04P Mounting holes (Bottom view) Tolerance: 0.1 (0.04)
3
G6D
s APPROVALS
UL (File No. E41515)/CSA (File No. LR31928) Type G6D-1A Contact form SPST-NO Coil ratings 5 to 24 VDC Contact ratings 5 A, 250 VAC (Resistive) 5 A, 30 VDC (Resistive) 1/10 HP, 120 VAC D150 Pilot Duty
G6D
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change.
Precautions
s SPACING BETWEEN RELAYS
More than two relays can be closely mounted right side up as shown in the illustration below.
s SOCKET MOUNTING
When mounting the relay, insert it into the socket as vertically as possible so that the relay terminals contact securely with the contact pins on the socket. The P6D-04P socket is flux-resistant. Do not wash the socket with water. Remove the relay from the socket before soldering the socket to a PC board. Mounting height
More than two relays can be closely mounted upside down as shown in the illustration below.
Note: The space between each relay required for heat radiation may vary with operating conditions.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
One East Commerce Drive Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. GC RLY7 01/00 Specifications subject to change without notice.
416-286-6465
Printed in the U.S.A.
4


▲Up To Search▲   

 
Price & Availability of G6D-1A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .